Journal of Aerosol Science ; 165:106045, 2022.
Article in English | ScienceDirect | ID: covidwho-1914540

ABSTRACT

A number of recirculating flow aerosol control technologies have been commercialized to mitigate aerosol-transmitted virus infections. Many of these technologies incorporate filters for particle collection and some may also incorporate technologies for virus inactivation. Given the wide variety of commercially available aerosol control technologies to consumers, it is extremely important to develop standardized methods to characterize their performance in bioaerosol removal and inactivation, such that technologies can be compared on an “equivalent-test” basis. However, no standard procedures have been established to evaluate the effectiveness of bioaerosol removal and inactivation in recirculating aerosol control technologies. We propose the use of a single-pass tunnel to assess the performance of bioaerosol control technologies, as single-pass wind tunnels can be sealed with well-controlled velocity and particle concentration profiles. Here, we specifically describe the construction of a single-pass wind tunnel and apply it to three recirculating aerosol control technologies, incorporating UV-C sources, filters, and electrostatic precipitators, respectively. We utilize a porcine respiratory coronavirus (PRCV) challenge aerosol, generated via pneumatic nebulization of a high titer (∼107 TCID50 mL−1) viral suspension. Following guidelines similar to those used in the ANSI/ASHRAE Standard 52-2 test procedure for HVAC filters, in single-pass wind tunnel tests, velocity uniformity and particle uniformity are first monitored across the cross-section of the tunnel. The size distribution of viable particles is additionally determined in advance of tests by the collection of particles in the wind tunnel using a cascade impactor, with both RT-qPCR and titration used to quantify viruses collected on each impaction stage. We show that the viable particle size distribution follows the volumetric size distribution of the nebulized virus-laden suspension, and that this distribution can be tuned to be similar in shape to the observed distribution of aerosol from human respiratory activities. Following tunnel and virus aerosol characterization, for each tested technology, using triplicate tests, the single-pass log reduction based on RT-qPCR and viable virus titration is determined by simultaneously collecting virus aerosol particles upstream and downstream of the control technology. The tested technologies in this study have titration-based single-pass log reductions in the 1.5–4.0 range. Overall, design and testing suggest that the single-pass wind tunnel approach is a tractable method to examine the efficacy of aerosol control technologies in removing and inactivating viruses in aerosols, and suggest that such technologies should be described by their single-pass log reduction and operating flow rate, with the test virus size distribution reported alongside test results. In addition, we examine the limits of detection in single-pass wind tunnel tests in comparison to chamber tests, and in doing so find that for most control technologies, the wind tunnel test will yield higher concentrations downstream or during sampling, and hence clearer results for the log reduction.

2.
Environ Sci Technol ; 55(7): 4174-4182, 2021 04 06.
Article in English | MEDLINE | ID: covidwho-1392752

ABSTRACT

Control technologies to inactivate airborne viruses effectively are needed during the ongoing SARS-CoV-2 pandemic, and to guard against airborne transmitted diseases. We demonstrate that sealed UV-C flow reactors operating with fluences near 253 ± 1 nm of 13.9-49.6 mJ cm-2 efficiently inactivate coronaviruses in an aerosol. For measurements, porcine respiratory coronavirus (PRCV) was nebulized in a custom-built, 3.86 m wind tunnel housed in a biosafety level class II facility. The single pass log10 reduction of active coronavirus was in excess of 2.2 at a flow rate of 2439 L min-1 (13.9 mJ cm-2) and in excess of 3.7 (99.98% removal efficiency) at 684 L min-1 (49.6 mJ cm-2). Because virus titers resulting from sampling downstream of the UV-C reactor were below the limit of detection, the true log reduction is likely even higher than measured. Comparison of virus titration results to reverse transcriptase quantitative PCR and measurement of fluorescein concentrations (doped into the nebulized aerosol) reveals that the reduction in viable PRCV is primarily due to UV-C based inactivation, as opposed to physical collection of virus. The results confirm that UV-C flow reactors can efficiently inactivate coronaviruses through incorporation into HVAC ducts or recirculating air purifiers.


Subject(s)
COVID-19 , Coronavirus , Aerosols , Humans , SARS-CoV-2 , Ultraviolet Rays
3.
Indoor Air ; 31(6): 2058-2069, 2021 Nov.
Article in English | MEDLINE | ID: covidwho-1222522

ABSTRACT

Recirculating air purification technologies are employed as potential means of reducing exposure to aerosol particles and airborne viruses. Toward improved testing of recirculating air purification units, we developed and applied a medium-scale single-pass wind tunnel test to examine the size-dependent collection of particles and the collection and inactivation of viable bovine coronavirus (BCoV, a betacoronavirus), porcine respiratory coronavirus (PRCV, an alphacoronavirus), and influenza A virus (IAV), by a commercial air purification unit. The tested unit, the Molekule Air Mini, incorporates a MERV 16 filter as well as a photoelectrochemical oxidating layer. It was found to have a collection efficiency above 95.8% for all tested particle diameters and flow rates, with collection efficiencies above 99% for supermicrometer particles with the minimum collection efficiency for particles smaller than 100 nm. For all three tested viruses, the physical tracer-based log reduction was near 2.0 (99% removal). Conversely, the viable virus log reductions were found to be near 4.0 for IAV, 3.0 for BCoV, and 2.5 for PRCV, suggesting additional inactivation in a virus family- and genus-specific manner. In total, this work describes a suite of test methods which can be used to rigorously evaluate the efficacy of recirculating air purification technologies.


Subject(s)
Air Filters , Air Pollution, Indoor , Coronavirus , Orthomyxoviridae/isolation & purification , Aerosols , Air Microbiology , Air Pollution, Indoor/analysis , Coronavirus/isolation & purification , Filtration/instrumentation , Oxidative Stress , Particle Size
4.
Am J Infect Control ; 48(10): 1237-1243, 2020 10.
Article in English | MEDLINE | ID: covidwho-623888

ABSTRACT

BACKGROUND: To mitigate potential exposure of healthcare workers (HCWs) to SARS-CoV-2 via aerosol routes, we have developed a portable hood which not only creates a barrier between HCW and patient, but also utilizes negative pressure with filtration of aerosols by a high-efficiency particulate air filter. MATERIAL AND METHODS: The hood has iris-port openings for access to the patient, and an opening large enough for a patient's head and upper torso. The top of the hood is a high-efficiency particulate air filter connected to a blower to apply negative pressure. We determined the aerosol penetration from outside to inside in laboratory experiments. RESULTS: The penetration of particles from within the hood to the breathing zones of HCWs outside the hood was near 10-4 (0.01%) in the 200-400 nm size range, and near 10-3 (0.1%) for smaller particles. Penetration values for particles in the 500 nm-5 µm range were below 10-2 (1%). Fluorometric analysis of deposited fluorescein particles on the personal protective equipment of an HCW revealed that negative pressure reduces particle deposition both outside and inside the hood. CONCLUSIONS: We find that negative pressure hoods can be effective controls to mitigate aerosol exposure to HCWs, while simultaneously allowing access to patients.


Subject(s)
Coronavirus Infections/prevention & control , Filtration/instrumentation , Infectious Disease Transmission, Patient-to-Professional/prevention & control , Pandemics/prevention & control , Personal Protective Equipment , Pneumonia, Viral/prevention & control , Respiratory Tract Infections/prevention & control , Adult , Betacoronavirus , COVID-19 , Coronavirus Infections/transmission , Equipment Design , Female , Filtration/methods , Health Personnel , Humans , Male , Pneumonia, Viral/transmission , Respiratory Tract Infections/transmission , SARS-CoV-2